Bently Nevada Module 3500/15

Bently Nevada Module 3500/15

Bently Nevada Module 3500/15 

The Bently Nevada 3500/15 is the primary power supply module for the 3500 Series Machinery Protection System. It provides stable, regulated DC power to all monitoring modules (vibration, displacement, speed, etc.) installed within the 3500 rack.

This module is a half-height design and must be installed in the leftmost slot of the 3500 rack, which is specifically reserved for power supplies.


Key Features

FeatureDescription
Physical FormHalf-height module; installs in the dedicated power supply slot on the left side of the rack
Redundancy SupportUp to two power supplies can be installed in one rack (lower slot = primary, upper slot = backup). In a redundant configuration, if the primary fails or is hot-swapped, the backup takes over seamlessly — ensuring uninterrupted system operation.
Hot-SwappableModules can be replaced without powering down the entire rack (when redundancy is active).
Operating Temperature–30 °C to +65 °C (–22 °F to +149 °F)
HumidityUp to 95% (non-condensing)

Power Supply Types

The 3500/15 is available in several variants to suit different site power conditions. Note: Legacy and new versions are not interchangeable with each other's Power Input Modules (PIMs) — always verify compatibility.

TypeInput Voltage RangeTypical Application
Universal AC85 to 264 VAC (47–63 Hz)Worldwide use; compatible with both 110V and 220V mains
High-Voltage DC88 to 140 VDCIndustrial DC power systems
Low-Voltage DC20 to 30 VDC24V DC systems; can be paired with AC supplies for redundancy

Model Number Breakdown

The 3500/15 ordering number follows the format: 3500/15-AXX-BXX-CXX

SegmentPositionOptionsMeaning
AUpper Slot (Primary)01 = Low AC (85–132 Vac)Power supply type installed in the upper (primary) slot


02 = High AC (175–264 Vac)


03 = High DC (88–140 Vdc)


04 = Low DC (20–30 Vdc)


05 = Universal AC (85–264 Vac)
BLower Slot (Backup)00 = No supply (single-configuration)Power supply type installed in the lower (backup) slot


Same coding as "A" above
CApprovals00 = No hazardous area certificationCertification level


01 = CSA/NRTL/C certified


02 = ATEX / IECEx / CSA (hazardous area)

Example: 3500/15-05-00-00 = Universal AC power supply in the upper slot (single supply, no backup, no hazardous area approval).